Servo Voltage Stabilizer
Servo Voltage Stabilizer is commonly observed that, AC main supply is never 230 Volt or 415 Volt, but varies from 150 Volt - 300 volt and 300 Volt - 500 Volt. The difficulties caused by them are well known, such as Over Load Condition, Line Losses, Poor Power Factor and several other reasons. Generally constant voltage which is required to load is never constant, but in fluctuation manner. It is observed that during the daytime, the voltage is quiet low and during the night the Voltage is high then the normal.
This fluctuation in supply system results frequent breakdown, low production and also loss of energy. The performance of any electrical equipment is optimum at its rated voltage. Both over / under voltages are harmful for the system. The under voltage reduces efficiency whereas the over voltage shortens the life.
The power agencies insist the consumer to fix the capacitor to improve power factor to get better results in power saving. But Voltage is far more important factor to save the power loss.
In case of very Low / High voltages, the telecom systems are powered by DG sets. Our Line Conditioner Unit meets the requirement of input voltage variation from 110V - 280V (Single phase) and 300V - 500V (Three phase). 240V - 500V is also available on demand.
In India, there are large voltage variations in the mains power supply. To overcome this problem, we are offering Line Conditioner Unit.

Capacity | 1 KVA to 2000 KVA |
Phase Input Voltage | 3 Phase 240-480V, 300-470V,340-460V 1 Phase 140-280V, 170-270V, 196-265V or any other Input ranges as per requirement of the Clients |
Input Frequency | 48 to 52 Hz |
Output Voltage | Three Phase 400V/415V+/-1% Single Phase 230/240V+/-1% |
Accuracy/ Regulation | +/-1% |
Output Frequency | 50 Hz |
Output Waveform | True to Input |
Voltage Correction Speed | 6V to 40 Volts (as per requirement) |
Response Time | Less than 10m/Sec. |
Correction Method | Step-less correction through variable Transformer |
Type og Cooling | ONAN |
Operating Temprature | 45 Degree C above ambient |
Insulation Class | 100% Continuous |
Efficiency | >/- 98% |
Auto Transformer | Copper Electrolytic Grae, Heavy Duty |
Buck Boost Transformer | Copper Electrolytic Grae, Heavy Duty |
Servo Motor | High Torque, Quick Response |
Suitability Type | Suitable for Three Phase Inbalanced/ Balanced Supply and Load |
Control Circuit | Fully automatic IC Based Solid Stat, glass epoxy control card for easy on line serviceability |
Digital Control Card | Having following features:- |
Display | Digital with Class 1 accuracy Input Voltage Output Voltage Output Current (Auto Scrolling) |
Auto Protection Alarm | Under Voltage, Auto Reset Over Voltage, Auto Reset |
Indications | Short Circuit & Password Protection
: Mains on Under Volt Over Volt Over Load |
Load Application | Capacitive, Resistive, any Combination of the load |
Component Losses | As per IS : 9815 |
Load Losses | As per IS : 9815 |
No Load Current | As per IS : 9815 |
Quality Process | ISO : 9001 (2008) |
IS Standard | IS : 9815, IS : 2026, IS : 335 |
Near water tank Nagar Nigam office behind raipur convent school khamatrai, Raipur-492002, Chhattisgarh, India
MON - SAT: 9.00 AM TO 6.30PM
SUNDAY: CLOSED